ONYX PolarStar 70

AED 16,600 + VAT

A ceiling-mounted ducted unit that treats filtered outdoor fresh air, circulates and purifies indoor air, discharges indoor air outdoors through a dedicated exhaust-air path, and dehumidifies automatically as indoor conditions require.

ONYX PolarStar 70 ceiling-mounted ducted fresh-air treatment and dehumidification unit

Ducted fresh-air treatment, air purification and dehumidification

ONYX PolarStar 70 is a ceiling-mounted ducted unit that combines filtered fresh-air treatment, indoor-air circulation and purification, a dedicated exhaust-air path for discharging indoor air outdoors, and automatically controlled dehumidification in a single machine. Air passes a primary filter and a high-efficiency HEPA filter before it is supplied to the property, and the dehumidification module engages automatically when indoor conditions call for moisture removal.

In automatic operation the unit switches between fresh-air mode, internal-circulation mode and internal-circulation mode with dehumidification according to indoor conditions. Air passes a primary filter and a high-efficiency HEPA filter before being supplied to the property; the dehumidification module engages when moisture removal is required, and condensate is removed by the integrated drainage lift pump. The unit also includes a dedicated exhaust-air path for discharging indoor air outdoors.

  • Filtered fresh-air treatment, indoor-air circulation, indoor-air exhaust and automatically controlled dehumidification in one ceiling-mounted unit
  • 70 L/day dehumidification capacity at the rated test condition of 30 °C, 80% RH
  • Primary filter and high-efficiency HEPA filtration stage
  • Four automatically switching operating states
  • Integrated drainage lift pump; RS485 Modbus control interface

Technical data

Published figures only.

Dehumidification capacity
70 L/day

Rated at 30 °C, 80% RH, measured in indoor-circulation dehumidification mode. Actual moisture removal on site depends on entering-air conditions.

Air volume
550 m³/h
External static pressure
120 Pa

External static pressure and input power are measured values at the rated air volume.

Power supply
220–240 V, 50 Hz
Rated power
0.95 kW
Maximum input power
1.5 kW
Refrigerant
R410A, 0.8 kg charge
Noise
44 dB(A)

Measured 1.5 m below the centre of the unit in a semi-anechoic chamber to GB/T 21087-2020.

Purification efficiency
≥98%

Manufacturer test value measured under the controlled conditions of GB/T 19411-2003 and GB/T 21087-2020.

Waterproof rating
IPX2
Unit weight
76 kg
Dimensions (L × W × H)
1220 × 765 × 285 mm

With L1 1263 mm, L2 1320 mm and W1 659 mm as shown on the manufacturer dimension drawing.

Duct connections
Ø200 mm

The duct connection diameter must not be changed. Duct connection accessories are not supplied with the unit.

Condensate drainage
Integrated drainage lift pump

The supplied insulated drain pipe is connected to the drain port of the integrated lift pump.

Operating range — dehumidification mode
15 to 32 °C
Operating range — fresh-air mode
−10 to 40 °C
Storage and transport
−20 to 60 °C
Installation method
Ceiling-mounted
Filtration
Primary filter and high-efficiency HEPA filter
Control and communication
Dedicated control panel; RS485 with Modbus protocol

Full technical specifications are available following project consultation.

Capacity figures apply under rated conditions.

Installation architecture

Ceiling-mounted installation above a false ceiling, connected to Ø200 mm ducts, with a maintenance opening of at least 600 × 600 mm at the maintenance door. Installation is carried out by qualified technicians.

Most ONYX NOVA solutions are concealed ducted systems installed separately from the air-conditioning system. ONYX Zenith may also be integrated into an air-conditioning or wider HVAC system where the project design allows.

Explore ONYX ducted dehumidifiers for UAE properties.

Operating states

  • Fresh-air mode — outdoor air treated and supplied, dehumidification module not activated
  • Internal-circulation mode — indoor air circulated and filtered, dehumidification module not activated
  • Internal circulation with dehumidification — dehumidification module activated
  • In automatic mode the unit switches between these states according to indoor conditions

Air paths

  • Fresh-air inlet drawing outdoor air into the unit
  • Return-air inlet drawing indoor air into the unit
  • Supply-air outlet delivering treated air to the property
  • A dedicated exhaust-air path for discharging indoor air outdoors

Installation requirements

  • Ceiling-mounted installation by qualified technicians, anchored with expansion bolts and M10 screws and levelled with a spirit level
  • At least 100 mm clearance above the unit and at least 60 mm between the underside of the unit and the finished ceiling
  • Maintenance opening of not less than 600 × 600 mm on the maintenance-door side
  • Connecting duct at the supply-air outlet of not less than 1 m
  • No more than three bends per duct run, formed as radiused elbows rather than 90° bends
  • Smooth, dust-free duct interiors and low-resistance grilles and louvres
  • Rain covers with insect mesh at all outdoor terminations; outdoor duct sections insulated and sealed with aluminium tape
  • The drain pipe must be insulated to prevent condensation
  • Wiring and grounding to local construction standards, with a three-core flexible cable of at least 1.0 mm² cross-section

Maintenance

  • Isolate the power supply before installation, maintenance or filter changes
  • Primary filter cleaned every one to three months, more often in dusty conditions; replace it after roughly three cleanings
  • Do not use a high-pressure water jet on the primary filter
  • The high-efficiency HEPA filter cannot be washed; a service life not exceeding three months is recommended, and the new filter is fitted in the direction of the label arrow
  • Check duct fittings, drainage connections and wiring periodically for looseness or damage

Important engineering limitations

  • Not for installation in atmospheres containing acids, alkalis or organic solvents
  • The unit must not be stored or transported tilted or inverted; allow it to stand for 2 hours before start-up
  • PolarStar 70 is a dehumidification and air-treatment unit; it does not replace an air-conditioning system and is not a room-cooling appliance

Technical notes

  • Specifications on this page are taken from the manufacturer product manual for ONYX PolarStar 70.
  • Rated performance figures are laboratory values obtained under controlled test conditions. Actual on-site performance depends on entering-air conditions, outdoor-air load, duct design and building use.
  • Final selection, duct design and installation arrangement are confirmed per project following a professional assessment.

Technical note: Final equipment selection and expected performance depend on site conditions, system design, outdoor-air conditions and professional assessment.

Talk to a specialist

Leave your contact details and an ONYX NOVA specialist will contact you to discuss your property and the most appropriate next step.

Contact